Pulsoksimetr KMP-RO50V is used for measurement of a pulse saturation of oxygen and pulse rate on a finger. The product is suitable for use in house and hospital conditions, oxygen bar, when rendering the medical and sanitary help to the population and medical examination and in sport (The device only to or after sports is recommended to be used).
The pulse saturation of oxygen (pulse saturation by oxygen) represents percentage of oxyhemoglobin (HbO2) in a total amount of hemoglobin (Hb) in blood, so-called content of oxygen (O2) in blood. It is the important biological parameter of breath. Many diseases of a respiratory organs can become the reason of decrease in arterial saturation of an organism oxygen (SpO2). Therefore, exact information on a saturation of patients gives significant assistance to doctors in detection of potential danger and is of great importance in the field of clinical medicine.
General characteristic:
- Simple and convenient management
- The product has the compact size, is easy and convenient at transfer.
- Display of indicators SpO2.
- Display of indicators of pulse rate, histogram display.
- Pulse form display.
- Function of a sound alarm signal
- Indicator of low power: The indicator of low power appears before the device begins to work incorrectly owing to low power
- Function of automatic shutdown: The product is automatically disconnected in the absence of a finger in the device more than 5 seconds when the device is in a condition of the measuring interface.
Technical characteristics:
Data on the display | Operating mode of the display |
Pulse saturation by SpO2 oxygen | Two-place organic LED display |
Pulse rate of PR | Three-digit organic LED display |
Intensity of pulse | Gistogrammny organic LED display |
Measurement of SpO2 | Range: 0% ~ 100% Accuracy: ±2% in the range of 70 ~ 100% of SpO2; value below of 70% is not defined. |
Pulse rate measurement | Range: The 30th blow in min. ~ the 250th blow in min. Accuracy: ±2 blows in mines or ±2% |
Clearness | 1% for SpO2 and 1 beat per minute for pulse rate |
Resistance to surrounding lighting | The deviation between the indicator measured at artificial or natural lighting indoors and the indicator measured in the dark room makes less than ±1%. |
Working tension | 3.6 Volt of a direct current ~ 4.2 Volts of a direct current. |
Light-sensitive sensor | Red light (wavelength – 660 nanometers ~ 6.65 MW) Infrared beam (wavelength – 880 nanometers, 6.75 MW) |
Adjustable range of a sound alarm signal | SpO2: 0% ~ 100% Pulse rate: 0 blow in min. ~ the 254th blow in min. |
Environmental conditions at storage | Temperature: - 40 ° C ~ +60os Relative humidity: 5% ~ 95% Atmospheric pressure: 500 gp ~ 1060 gpa |
Service conditions | Temperature: 10 ° C ~ 40 ° C Relative humidity: ≤75% Atmospheric pressure: 700 gp ~ 1060 gpa |
Dimensions | 46(D) × 40(Sh) × 29(V) of mm |
Weight | About 35 g (together with lithium batareykoy*1) |