(View map)
USE IN THE PLACE OF DELIVERY OF HEALTH CARE:
Anesthesia, intensive care and reanimation, obstetrics and gynecology, urgent medicine, management of installation of the central venous catheters (CVC), researches of skeletal and muscular system and vessels, surgery.
OVERVIEW OF THE MAIN OF FUNCTION
- Visualization with high resolution and full color Doppler mapping
- The user interface with the touch screen
- Moisture impermeability for convenience of cleaning and disinfection
- The advanced control system — pressing of only one button
- Unsurpassed durability — the Equipment is tested for resistance to shock loading when falling from height of 91,4 cm
- Resistance to external influences and small weight — 2,7 kg
TECHNICAL CHARACTERISTICS OF SYSTEM
ULTRASONIC NANOMAXX® SYSTEM OF PRODUCTION SONOSITE
DESCRIPTION OF THE PRODUCT:
Weight of system |
2,7 kg (with the accumulator) |
Sizes |
35,8 x 20,8 x 5,8 cm (Dkh Vkh Sh) |
Display |
the touch LCD screen with the diagonal of 21,3 cm / 8,4" |
Start time |
less than 20 seconds |
Architecture |
completely digital, broadband |
DURABILITY
The equipment is tested for resistance to shock loading when falling from height of 91,4 cm
VISUALIZATION MODES:
2D, TsDK, color power doppler, M - mode
FUNCTIONS OF OPTIMIZATION OF THE IMAGE:
Mode of fabric harmonics (THI), SonoADAPT", SonoMB®, SonoHD", technology of automatic adjustment of strengthening (algorithms)
USER FUNCTIONS OF SETUP OF THE IMAGE:
- Adjustment of depth, strengthening; scale (double increase, the block of panning and scaling in the freeze frame mode) SonoMB®, THI
- Viewing of images — in the modes 2D, TsDK, a color power doppler, and also in the M - mode
- Settings of optimization of the image — permission, the general optimization, penetration depth
- TsDK module and color power doppler
ADDITIONAL COMPONENTS:
Program SonoCalc® 1mtdlya component of measurement of thickness of a complex of erotic media of a carotid artery
MEASUREMENTS:
2 measurements of distance on a straight line — the instrument of measurement of thickness of a complex of erotic media of a carotid artery (CIMT) Obstetric calculations
COMMENTS:
- Pictograms for research designation: researches of abdominal organs, vessels, gynecologic and obstetric researches, researches of small bodies, cardiological and neurologic researches, researches of superficial organs, measurement of CIMT, research of veins
- Four options of an arrangement of the pictogram on the screen are provided
- There are three libraries of ready text designations for each type of researches
- There are edited libraries of text designations (with a total amount up to 90 designations)