"Oxy 500" of the Oxy 500 DP model, 500 FB, 500 FBW Pulsoksimetr (Trismed, South Korea) is used for determination of saturation rate by oxygen of hemoglobin of blood of the patient and heart rate on a finger, at dysfunction of self - control of the bodies, postoperative injuries and injuries got during medical examination.
The device is applicable in house conditions, hospitals, in oxygen bars, the public medical organizations, for carrying out medical examinations at sports activities.
Pulsoksimetr differs in the small sizes, low energy consumption, usability and convenience when carrying. The patient needs to place only a finger in the device which is reading out data as on the screen there will be corresponding indications of saturation rate hemoglobin oxygen possessing high precision.
FEATURES:
- It is simple and convenient to work with the device
- The device has the insignificant volume and weight, it is convenient for carrying
- Energy consumption of the device is insignificant
- SPO2 value display
- Pulse rate display, display of histograms
- Display of a pulse shape
- Indication of a low voltage: indication of a low voltage appears before the device begins to work incorrectly because of a low voltage
- Function of automatic power off: when performing by the device of changes, it will automatically power off within 5 seconds if the finger of the patient is not in the sensor for measurement
- The browse mode can be changed
- Brightness of the screen can be changed
- Sound indication of pulse rate
- Has function of an alarm signal
- SpO2 values (saturation rates oxygen of hemoglobin of blood of the patient) and pulse rates can be kept
- The data which are stored in the device can be unloaded on the computer. Data in real time can be transferred to the computer
MODEL 500 FB
- Measurement of SpO2: measuring range: 0% ~ 100% ;
- Image: 128×96 points, true color display: OLED, 4 measurements;
- Visual and audioalarm signal.
- Pulse rate measurement: measuring range: 30 beats per minute ~ 250 beats per minute;
- USB and function of the wireless interface (type 500 FBW);
- The synchronous display on an oksimetra and the computer.
- Memory size: 30 hours. ON for the personal computer for inspection and monitoring of the patient during a dream.
- Indication of tension in the battery.
- USB and AC charger.
- SpO2 accuracy: ±2% in the range of 70% ~ 100% .
- Automatic shutdown after 4 sec.
- The recharged lithium battery – 3,7B.
- Sizes (mm): 57 (D) ×32 (Sh) ×30 (In).
- Weight: 50 g (including the lithium battery ×1)
MODEL 500 DP
- Display: OLED, two colors, 128×64 points.
- Alcaline battery, AAA size, 1,5B - 2 of piece
- USB port, synchronization with analyzing ON on the personal computer.
- Built - in memory: 24 hours
Technical characteristics:
Measurement of SpO2 |
Measuring range: 0% ~ 100% Accuracy: 70% ~ 100% , ±2% ; 0% ~ 69% , without definition |
Pulse rate measurement |
Measuring range: 30 beats per minute ~ 250 beats per minute Accuracy: ±2 beats per minute or ±2% (choose bigger value) |
Permission |
SpO2: 1% , pulse rate: 1 beat per minute |
Performance of measurements in the conditions of low perfusion: |
SpO2 and pulse rate can be shown correctly at coefficient of filling of pulse, equal 0,4% . The amendment for SpO2 makes ±4% , the amendment for pulse rate makes ±2 beats per minute, or ±2% (choose bigger value). |
Requirements to power supplies |
3,6 V. of a direct current ~ 4,2 V. of a direct current. |
Optical sensor |
Red light (wavelength: 660 nanometers. , 6,65 MW. ) Infrared (wavelength: 880 nanometers. , 6,75 MW. ) |
Range of setup of an alarm signal: |
SpO2: 0% ~ 100% Pulse rate: 0 beats per minute ~ 254 beats per minute |